Ethernet Option

Programming Procedure

u

Configure Communication (Comm) Settings:

Press

P 8 3

to access Comm settings

a. Use the keypad to Enable DHCP or Disable to select static IP entry.

• Press

1

for enable DHCP

• Press

2

for disable DHCP

• Press

O

to accept

• If

1

skip to e

b. Use the keypad to enter the Unit IP Address. This is a static address

assigned by your Network Administrator. Enter preceding zeros as

necessary.

• Press

O

c. Use the keypad to enter the Subnet Mask. Enter preceding zeros as

necessary. This is the subnet mask of your network.

• Press

O

d. Use the keypad to enter the Gateway IP. Enter preceding zeros as

necessary. This is the IP address of your network's Gateway device.

• Press

O

e. Use the keypad to enter the Time Server Address. Enter

preceding zeros as necessary. Press

O

.

OR Press

O

to accept the default set at the factory from the list of

known good Internet Time Servers in Appendix A.

f. Use the keypad to enter the Alternate Time Server Address.

Enter preceding zeros as necessary. Press

O

.

OR Press

O

to accept the default set at the factory from the list of

known good Internet Time Servers in Appendix A.

g. The unit will prompt you to enter the Port Number. This is for Remote

Connect web access and should be set to 0080.

Press

O

to accept the default (80) set at the factory.

h. Press:

OBB

, to return to Main Screen.

v

Sync System Controller with correct time & date:

a. Press:

P1

, to Set Menu Mode.

b. Enter User Lock and press

O

.

c. Press:

9

, to sync the System Controller with Ethernet. Press

>

until

Ethernet option is chosen.

d. Press

8

to sync with Ethernet.

n

Note: If "Ethernet Sync Successful" is displayed, press

OBB

to return

to Main Screen.

If "Ethernet Sync Failed" is displayed, reference the troubleshooting guide.

w

The Ethernet sync option is now configured and will update the time on the

System Controller automatically once each hour at a time preset at the factory.

n

Note: When Ethernet synchronization is working, ETH=S will be displayed on

the screen in small text mode as shown in screen shot

3

. If a synchronization

attempt fails, ETH=N will be displayed.

MON MAR 10 2014
10:38:06 AM USCT
American Time
Status=AUTO ETH=Y

Glossary

Appendix

Troubleshooting

Clock

Installation

System Contr

oller

Installation

Intr
oduction

Turn on the power to the System Controller

n

Note: These settings may already have been

entered using the Startup Wizard.

Comm Menu

Unit IP Address

192.168.001.001

<=BkSp OK=Done

Comm Menu

Enter Subnet Mask

255.255.255.000

<=BkSp OK=Done

Comm Menu

Time Server Address

137.107.013.100

<=BkSp OK=Done

Comm Menu

Enter Port Number

for web access:0080

OK=Done

Comm Menu

Enter Gateway IP

192.168.010.099

<=BkSp OK=Done

1g

1d (example)

1c (example)

1e (example)

1b (example)

1a

Set Menu Mode

Enter User Lock:

xxxx

PROG=EXIT

OK=ENTER

Set Menu Mode

Time Sync Option is

Available: Ethernet

8=Sync now

OK=Set

2b

2c and d

MON MAR 10 2014

10:30:06 AM USCT

American Time

Circts=Auto ETH=S

3

Comm Menu

DHCP

1=Enable

2=Disable Ok=Done

1f

Comm Menu

Alt Time Srvr Addr

173.014.055.009

<=Bksp

Ok=Done