SiteSync IQ Installation Manual

Wireless Analog Clock Installation

Wireless Analog AC Clocks

Wireless Analog AA Battery Clocks (DC)

n

Note: SiteSync IQ clocks ship with batteries installed. Do not connect the barrel

jack plug to the receiver until the master is installed and transmitting.

u

Connect the barrel jack plug of the battery pack to the wireless receiver.

v

The LED on the back of the clock will turn red for 1 second then briefly

flash orange (1-15 flashes) indicating the receive frequency on power up.

Within 30 seconds of power up the LED will flash red or green. Red

indicates the receiver is looking for the signal and green indicates the

signal has been received. When the movement starts to correct, the LED

will turn off.

n

Note: If the LED does not flash within 30 seconds, remove barrel jack plug

of the battery pack from the receiver, wait for 5 seconds and reconnect it. The LED

should begin flashing within 30 seconds.

w

Within 3-5 minutes after activation, the green LED will stop flashing and

the clock hands should rapid advance to the correct time. If clocks do not

synchronize within 10 minutes of battery activation, see

n

Note in

step 2.

x

Hang the clock using the keyhole hanger on the back of the clock or the

security bracket (sold separately).

y

Continue clock installation. Follow steps 1-4 for the remainder of your

clocks. You may skip step 3 and confirm clock synchronization after

some or all clocks have been hung.

n

Note: Clocks will only attempt to sync to the System Controller at

approximately 2 (am & pm) and 8 (am & pm)

as displayed on the clocks

and after initial power up.

Note: Do not connect power to the clocks until the System Controller is installed

and transmitting.

u

Connect clocks to AC power with cord or Molex kit and confirm green

LED is lit after power-up.

v

The LED on the back of the clock will turn red for 1 second then briefly

flash orange (1-15 flashes) indicating the receive frequency on power up.

Within 30 seconds of power up the LED will flash red or green. Red

indicates the receiver is looking for the signal and green indicates the

signal has been received. When the movement starts to correct, the LED

will turn green.

n

Note: If the LED does not flash within 30 seconds, press the reset button on the

clock receiver. The LED should begin flashing within 30 seconds.

w

Within 3-5 minutes after power-up, correction should begin and the

clock hands should advance to the correct time. If clocks do not

synchronize within 20 minutes of power-up, see

n

Note in step 2.

x

Hang the clock using the keyhole hanger on the back of the clock or the

security bracket (sold separately).

y

Continue clock installation. Follow steps 1-4 for the remainder of your clocks.

You may skip step 3 and confirm clock synchronization after some or all clocks

have been hung.

n

Note: Clocks will only attempt to sync to the System Controller at approximately

2 (am and pm) and 8 (am & pm)

as displayed on the clocks and after initial

power-up or reset.

Glossary

Appendix

Tr

oubleshooting

Clock

Installation

System Contr

oller

Installation

Intr

oduction

AC

DC

To

wiring

box

AC

DC

To

wiring

box

LED

Barrel

Jack

Input

Optional

Security

Bracket

(12" shown)

Reset

Button

LED

120vac model shown

For both battery and AC clocks, we recommend first installing one clock near the

master and then one at the furthest location. Then install the remaining clocks in their

designated locations. This will simplify system troubleshooting.
Clocks should be installed within 24 hours of installing the system controller. After 24 hours, the system controller will enter Quiet Mode.

Pressing 3-5-7 on the keypad will disable Quiet Mode for 6 hours. Reference Appendix J for more details on Quiet Mode.