23

© American Time

SiteSync IQ Installation Manual

Set Menu Time Zone

Configure TZONE (1-8)

LOCAL = USCT

< >=Scroll

OK=Accept

Set Menu Options

1=Time

2=Date

3=Time Zones & DST

4=12/24

9=Sync Now

Set Menu

Enter User Lock:

xxxx

PROG=Exit

OK=Enter

u

Press:

P1

. Enter the User Lock. Press

O

.

v

Press

3

to enter Time Zones & DST Menu.

w

To select the time zone

a. Use the

<>

keys to select the time zone to configure (1-8).

0=Local 1=TZ1 2=TZ2 3=TZ3

4-TZ4

5=TZ5 6=TZ6 7=TZ7 8=TZ8

n

Important Note: This feature requires clock receiver configuration by

the factory.
b. Select TZONE time zone by using the

<>

or enter a time

zone code from Appendix B. Press

O

.

If a custom time zone is needed, press

99

and

O

and reference

Setup Wizard Step 4 (page 10). Reference Setup Wizard Step 5 (page 10) to
configure DST.

x

Repeat Steps 1-4 for additional time zone clocks.

3a and b

2

1

Programming Procedure

This feature allows for up to 8 additional time

zone clocks.

Glossary

Appendix

Troubleshooting

Clock

Installation

System Contr

oller

Installation

Intr
oduction

Turn on the power to the System Controller

Time Zone Clocks Option

Eastern Central Mountain Pacific

Time Zone Clocks Example:
This example will demonstrate how to set up two time zone clocks. This feature requires clock receiver configuration by the factory. The first
clock will be set as TZONE1 and will be set to represent London Time (UTC+0). The second clock will be set as TZONE2 and will be set to
represent Tokyo time (UTC+9).
Clock TZONE1:
1. Press

P1

and enter User Lock (if applicable).

2. Press

3

to enter Time Zone & DST.

3. Use

<>

keys to select TZONE1 and press

O

.

4. Use the

<>

keys to select Time Zone Code 14 (UTC+0) or use the keypad to enter 14 and press

O

.

Note: Reference Appendix B for supported time zones.

5. Press

9

for Custom DST settings and press

O

.

6. Press

2

for Floating Dates.

Note: In the European Union, Summer Time begins at 1:00 AM Universal Time (UTC) and ends at 2:00 AM Summer Time 1:00 AM

UTC). It begins the last Sunday in March and ends the last Sunday in October. In the EU, all time zones change at the same moment.

7. Select LAST SUN of MAR using the

<>

keys and pressing

O

between selections.

8. Set the BIAS to +1:00 by pressing

100O

.

9. Press

O

to accept.

10. Enter the DST Start Time

100

and select AM using the

<>

keys.

11. Press

O

.

12. Select LAST SUN of OCT using the

<>

keys and pressing

O

between selections.

13. Press

O

to accept.

14. Enter the DST End Time

200

and select AM using the

<>

keys.

15. Press

O

.

TZONE1 is now configured. Any wireless clocks configured for TZONE1 will correct to London time on power-up or reset.
Clock TZONE2:

1. Use the

<>

keys to select TZONE2 and press

O

.

2. Use the

<>

keys to select Time Zone Code 23 (UTC+0) or use the keypad to enter 23 and press

O

.

Note: Reverence Appendix B for supported time zones.

3. Press

0

for turning DST off.

Note: Japan does not have DST.

4. Press

O

.

TZONE2 is now configured. Any wireless clocks configured for TZONE2 will correct to Tokyo time on power-up or reset.