Wireless digital clock installation, Digital single display flush mounting – American Time SiteSync IQ User Manual

Page 53

Advertising
background image

53

© American Time

SiteSync IQ Installation Manual

Wireless Digital Clock

Installation

Glossary

Appendix

Troubleshooting

Clock

Installation

System Contr

oller

Installation

Intr
oduction

n

Note: Time format (12 or 24 hour) for Wireless Digital Clocks is set at the SiteSync IQ system controller. The format displayed on the

system controller will display on the digital clocks.

CAUTION: RISK OF ELECTRICAL SHOCK - Disconnect and lock out power to the

electrical box before installing or servicing the clock.

u

Remove the hanger from the clock by removing the screw on top of the clock.

v

Mount the hanger on the wall to a single or double gang box.

w

Make electrical connections (black to hot, white to neutral and green to ground)

for the Molex cable (not wired to the clock) to a non-switched electrical circuit

wiring using UL approved wire nuts. Route field wiring away from sharp

projections and corners.

x

Join the wall and clock Molex together.

y

Mount the clock on the hanger and secure with the screw removed in Step 1.

z

Remove plastic protector from display face.

Apply power to the circuit and confirm correct operation.

Digital Single Display Surface Mounting

Digital 2-Sided Display - Ceiling or Wall Mount

u

Make electrical connections (black to hot, white to

neutral and green to ground) for the Molex cable (not

wired to the clock) to non-switched electrical circuit

wiring using UL approved wire nuts. Route field wiring

away from sharp projections and corners.

v

Join the wall/ceiling and clock Molex together.

w

Mount the clock to the ceiling (4" box) or wall (single or

double gang box).

x

Remove plastic protector from display face.

y

Apply power to the circuit and confirm correct operation.

Digital Single Display Flush Mounting

CAUTION: RISK OF ELECTRICAL SHOCK - Disconnect and lock out power to the

electrical box before installing or servicing the clock.

u

Remove the four sheet metal screws that hold the cover assembly and

enclosure base together. Be sure to keep the sheet metal screws for

reassembly.

v

Mount the enclosure base into the wall. Opening is 12

1

2

" x 7

1

2

" x 3

1

2

".

w

Run interconnecting field wires through the enclosure base.

x

Make electrical connections (black to hot, white to neutral, green to ground

wires) to non-switched electrical circuit wiring using UL approved wire nuts.

Route field wiring away from sharp projections, corners and internal

components.

y

Join both Molex connectors together, placing excess wiring and Molex

connectors into the box.

z

Re-attach the cover assembly to the enclosure base using the sheet metal

screws removed in Step 1.

Remove plastic protector from display face.

Apply power to the circuit and confirm correct operation.

CEILING

CAUTION: RISK OF ELECTRICAL SHOCK - Disconnect and lock out power to the

electrical box before installing or servicing the clock

Advertising