System controller installation – American Time SiteSync IQ User Manual

Page 6

Advertising
background image

© American Time

6

SiteSync IQ Installation Manual

Glossary

Appendix

Tr

oubleshooting

Clock

Installation

System Contr

oller

Installation

Intr

oduction

Back - UPS ES 550

Surge Pr

otection

Power On

Replace Battery

Battery Backup+

Surge Protection

System Controller Installation

MON MAR 10 2014
10:38:06 AM USCT
American Time
Status=AUTO CDMA=S

server rack

Shown with optional rack mount

option, Part No. H004100

System Controller with Internal Transmitter and Magnetic Mount Antenna

The Magnetic Mount antenna is standard equipment with 5 and 10 watt internal transmitter systems.

1. Choose a suitable location for the System Controller, following the safety precautions on Page 1:
a. Place the System Controller indoors.
b. Locate within 10 ft. of planned location for antenna.
c. Locate near an electrical outlet (120vac).
d. Rack or shelf mount.
e. If you have a sync option, review the applicable installation guidelines included in this manual.
2. Install the magnetic mount antenna per the instructions on Page 6.
3. Connect the cables to the System Controller:
a. Connect the antenna cable to the TX ANT port.
b. Connect the power supply to the POWER INPUT port.
c. Connect the power supply to 110v electrical supply (American Time recommends using surge protector/battery

backup Part # H002717A shown).
4. Turn on the power to the System Controller:
a. Place the rocker switch on the back of the unit to the ON position as shown above.
b. Confirm that the backlit display on the front of the unit lights up and displays text.
5. Follow the Setup Wizard instructions on pages 9-12.

n

Note: Follow these instructions for System Controllers ordered without a transmitter (for wired operation only), except disregard steps 1b

and 3a.

Part #H002717A

Advertising