SiteSync IQ Installation Manual

Contact Closure Sync Option

Turn on the power to the System Controller

u

Set the SiteSync IQ System Controller to be a transmitter (Tx) of the

contact closure. Press

P9

to enter Master to Master Menu.

v

Enter User Lock. Press

O

.

w

a. Press

1

to set the SiteSync IQ System Controller to Tx.

b. Enter transmit duration in milliseconds (0-9999). Press

O

.

Example: 2,000ms=2 seconds

x

Using the keypad, set the time when the contact closure should

occur. Use

<>

to select AM or PM. Press

O

.

n

Note: Reference existing equipment instruction manual for contact closure

time. These closure time and duration settings are also used for the wireless
Master Synchronizer (optional, ATS Part # H004228).

n

Note: Wireless Master Synchronizer transmissions round uup to the

nearest second. Example: 2,005ms = 3 seconds

n

Important Note! The Sync Time set in Step 4 must be the same for

both units.

Turn on the power to the System Controller

u

To set the SiteSync IQ System Controller to be a receiver (Rx) of the

contact closure. Press

P9

to enter Master to Master Menu.

v

Enter User Lock. Press

O

.

w

a. Press

2

to set the SiteSync IQ System Controller to Rx.

x

Using the keypad, set the time when the existing equipment

performs a contact closure. Use

<>

to select AM or PM.

Press

O

.

n

Note: Reference existing equipment instruction manual for contact closure time.

Comm Menu MTM Sync

Transmit Duration:

50 ms

OK=Done

Comm Menu MTM Sync

Master to Master:

1=Tx

3=Off

2=Rx

Comm Menu MTM Sync

Sync Time:

12:00:00 AM

<>AM/PM

OK=Done

Comm Menu

Enter User Lock:

____

PROG=Exit OK=Enter

4

3a

3b

2

Existing Equipment Providing 2 Wire Synchronization

SiteSync IQ System Controller providing 2 Wire
Synchronization

(refer to screen shots above)

Installing Contact Closure Sync Option

This option allows a SiteSync IQ System Controller to be synchronized with existing equipment with a contact closure. This type of

synchronization can also be implemented between two SiteSync IQ System Controllers.

existing equipment

Transmitting IQ System Controller

COM

NO

NC

NC

COM

NO

NO

COM

COM

NO

NO

COM

NO

COM

NO

COM

CLOCK 1

CLOCK 2

BELL 1

BELL 2

BELL 3

BELL 4

BELL 5

BELL 6

NO

COM

Input

Contact Closure

Output (Circuit 6)

Note: Circuit 6 will not

be operable for use as

a signal circuit when

Tx synchronization is

enabled.

Glossary

Appendix

Troubleshooting

Clock

Installation

System Contr

oller

Installation

Intr
oduction

existing equipment

existing equipment

Rx IQ System Controller

Transmitting IQ System Controller

surge protector switch

NC

NC

CO

M

NO

NO

CO

M

CO

M

NO

NO

CO

M

NO

CO

M

NO

CO

M

CL

OCK 2

BELL 1

BELL 2

BELL 3

BELL 4

BELL 5

BELL 6

NO

CO

M

Input

Contact Closure

Output

Input Connection

1

2

3

Programming Procedure

This option uses the existing system with contact closure

(i.e. Phone/Intercom System, Master Clock, Synchronizer,

etc.) to synchronize a SiteSync IQ System Controller. Connect

wiring as shown in the diagram at right.

This option uses a SiteSync IQ System Controller to sync existing

equipment supporting contact closure input. Connect wiring as shown in

the diagram below.

MON MAR 10 2014
10:38:06 AM USCT
American Time
Status=AUTO ETH=Y

Advertising
This manual is related to the following products: