Get Sensor Reading Factors
Sensor/Event
04, 05
23
Set Sensor Hysteresis
Sensor/Event
04, 05
24
Get Sensor Hysteresis
Sensor/Event
04, 05
25
Set Sensor Thresholds
Sensor/Event
04, 05
26
Get Sensor Thresholds
Sensor/Event
04, 05
27
Set Sensor Event Enable
Sensor/Event
04, 05
28
Get Sensor Event Enable
Sensor/Event
04, 05
29
Rearm Sensor Events
Sensor/Event
04, 05
2A
Get Sensor Event Status
Sensor/Event
04, 05
2B
Get Sensor Reading
Sensor/Event
04, 05
2D
Set Sensor Type
Sensor/Event
04, 05
2E
Get Sensor Type
Sensor/Event
04, 05
2F
Get Device ID
Application
06, 07
01
Broadcast 'Get Device ID'
Application
06, 07
01
Cold Reset
Application
06, 07
02
Warm Reset
Application
06, 07
03
Get Self Test Results
Application
06, 07
04
Get Device GUID
Application
06, 07
08
Reset Watchdog Timer
Application
06, 07
22
Set Watchdog Timer
Application
06, 07
24
Get Watchdog Timer
Application
06, 07
25
Send Message
Application
06, 07
34
Get FRU Inventory Area Info
Storage
0A, 0B
10
Read FRU Data
Storage
0A, 0B
11
Write FRU Data
Storage
0A, 0B
12
Get PICMG Properties
PICMG
2C, 2D
00
Get Address Info
PICMG
2C, 2D
01
Table 7-5 IPMC IPMI Commands (continued)
Command
netFn
LUN
Cmd