10 get payload communication time-out, 10get payload communication time-out, Table 7-26 – Artesyn ATCA-9305 User's Manual (May 2014) User Manual
Page 178: Get payload communication time-out command, System management

System Management
ATCA-9305 User’s Manual (10009109-07)
178
7.11.10 Get Payload Communication Time-Out
The Get Payload Communication Time-Out command reads the payload communication
time-out value.
Response Data
1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Table 7-25 Set Handle Switch Command (continued)
Type
Byte
Data Field
Table 7-26 Get Payload Communication Time-Out Command
Type
Byte
Data Field
Request Data
1:3
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
Response Data 1
Completion Code
2:4
PPS IANA Private Enterprise ID, MS Byte first
0x00400A = 16394 (Pigeon Point Systems)
5
Payload Time-out
Payload communication time-out measured in hundreds of
milliseconds. Thus, the payload communication time-out may vary
from 0.1 to 25.5 seconds.