7.10.3 Set FRU LED State Command
The Set FRU LED State command allows the state of the FRU LEDs to be controlled by the
management system.
Table 7-14 Set FRU LED State Command
Type
Byte
Data Field
Request Data
1
PICMG Identifier—indicates that this is a PICMG defined group extension
command. Use value 00h.
2
FRU Device ID
3
LED ID
00h Blue LED (Hot Swap)
01h LED 1 (OOS)
02h LED 2
03h LED 3
04h-FEh OEM defined LEDs
FFh Lamp Test (all LEDs under management control are addressed)
4
LED Function
00h LED off override
01h-FAh LED blinking override
FBh Lamp Test state Turn on LED specified in byte 3 for the duration
specified in byte 5, then return to the highest priority state.
FCh LED state restored to Local Control state
FDh-FEh reserved
FFh LED on override
5
On Duration
LED on-time is measured in tens of milliseconds
Lamp Test time in hundreds of milliseconds if byte 4=FBh, time value
must be less than 128. Other values when Byte 4=FBh are reserved.
Otherwise, this field is ignored and shall be set to 0h.