5-6 Programmer’s Manual

Field

Description

uchEnableC32Prefix

Enable/disable the ability to add “A” as a
prefix to all Code 32 bar codes. You must
enable uchCvtC39toC32 when enabling
this parameter.
Default: SCN_DISABLE

uchLength1
uchLength2

Specifies lengths (including check digits)
for Code 39 bar codes. You can specify
one or two lengths, a range of lengths, or
that any length is valid. If
uchEnableFullASCII is enabled, a range or
any length is preferred. Enter values as
follows:

Option

uchLength1 uchLength2

1 Length

Value

0

2 Lengths

High Value Low Value

Range

Min. Value

Max. Value

Any length

0

0

Default: 2 (uchLength1) and 55
(uchLength2)

uchVerifyCheckDigit

Enable/disable the ability to check the
integrity of Code 39 bar codes. When this
parameter is enabled, only Code 39
symbols with a modulo 43 check digit are
decoded.
Default: SCN_DISABLE

uchXmitCheckDigit

Enable/disable the ability to transmit check
digits with the data.
Default: SCN_DISABLE

uchEnableFullASCII

Enable/disable the ability to scan Full
ASCII Code 39 bar codes. The scanner
cannot distinguish Code 39 bar codes from
Full ASCII Code 39 bar codes. Do not
enable uchEnableTrioptic and
uchEnableFullASCII at the same time.
Default: SCN_DISABLE