Avery Dennison 6035 Programmer Manual Rev.CA 6/01 User Manual
Page 180
Data Structure Reference 5-21
Field
Description
uchUPCACD
Enable/disable the return of UPCA
check digits with scanned data.
Default: SCN_ENABLE
uchUPCPSysOnly
Enable/disable the return of the system
character (and not the country code)
with UPCE and UPCA scanned data.
You must disable uchUPCPNone when
enabling this parameter.
Default: SCN_DISABLE
uchUPCPNone
Enable/disable the return of the system
character and country code with
scanned data.
Default: SCN_DISABLE
uchI2of5Len1 and
uchI2of5Len2
Sets the lengths of the I 2 of 5 bar
codes to scan. Values are 0-31. The
application must also set uchI2of5 to
SCN_ENABLE.
Default: 14 (for uchI2of5Len1)
0 (for uchI2of5Len2)
For the fields where you enable or disable
an option, the values are SCN_ENABLE and
SCN_DISABLE.
You cannot scan two-dimensional bar codes.
See “scnGetScanInfo” or “scnSetScanInfo” in Chapter 4 for
more information.