Avery Dennison 6035 Programmer Manual Rev.CA 6/01 User Manual

Page 183

Advertising
background image

5-24 Programmer’s Manual

Field

Description

uchEnableSuppRedun

The number of times to scan bar codes
without supplementals before
transmission. Five or more is
recommended when scanning a mix of
UPC/EAN bar codes with and without
supplementals. You must set
uchEnableSupps is set to 2 when setting
this parameter. Single digit numbers
must have a leading zero. Values are 2-
20.
Default: 7

uchXmitUPCAChkDgt

Enable/disable the requirement to
transmit UPCA bar codes with the check
digit.
Default: SCN_ENABLE

uchXmitUPCEChkDgt

Enable/disable the requirement to
transmit UPCE0 bar codes with the
check digit.
Default: SCN_ENABLE

uchXmitUPCE1ChkDgt

Enable/disable the requirement to
transmit UPCE1 bar codes with the
check digit.
Default: SCN_ENABLE

uchUPCAPreamble

Specifies how to transmit lead-in
characters for UPCA bar codes. Values
are:

0

Do not transmit

1

Transmit system character

2

Transmit system character and

country code

Default: 1

Advertising