Avery Dennison 6035 Programmer Manual Rev.CA 6/01 User Manual

Page 118

Advertising
background image

Function Reference 4-77

s c n S e t C o d e 1 2 8 I n f o

Description

SCAN1223.LIB only. Saves the 1223 scanner configuration
values the application set in the CODE128INFO data structure.
See “CODE128INFO” in Chapter 5 for a description of this data
structure.

To configure the scanner, the application

1. Enables the scanner with scnOpenScanner or

scnOpenScannerShared.

2. Calls scnGetCode128Info.

3. Sets the values in the CODE128INFO data structure.

4. Calls scnSetCode128Info.

When the application disables the scanner,

the configuration values go back to the

defaults.

Syntax

short far scnSetCode128Info(LPCODE128INFO lprCode128Info);

Parameters

lprCode128Info

A pointer to a CODE128INFO data structure.


Return Values

0

Successful.

-5

Invalid configuration value.

-9

The scanner is disabled.

Advertising