Operating Instructions Automatic Multi-Head Serging Machine 1365-4

Beisler GmbH

B-19

B.3

Operation

B.3.1 Preparing the machine

Prior to a production start, check the supply connections, connect the ma-

chine to the compressed air system and to the power supply system, and

prepare the sewing head.

1. Connect the machine to the power supply system.

WARNING - Electric shock!

Contact with current-carrying components may cause a le-

thal electric shock. Check plug and cable before connecting

machine to power supply system.

• Do not use damaged plugs, sockets or cables to con-

nect the machine to the power supply system!

• The machine is operated with a supply voltage of 230 V

± 10 % at 50/60 Hz. The power supply cable must have

a minimal cross section of 1,5 mm.

• Before connecting the machine to the power supply sy-

stem, check to see if the ratings of the power supply

system in the operating room correspond with the ra-

tings on the nameplate at the rear of the machine.

• If the ratings for voltage (V) and maximum current (A)

do not match, the machine must not be connected.

• Insert the grounding plug into a properly grounded and

fused power socket.

• Make sure that the power supply cable is not subjected

to tensile or pressure forces.

2. Switch the machine on by moving the main switch to position I. After

the machine has been switched on, its control program is powered up.

The display shows the most recently selected sewing program.

3. Switch the heating module on. Wait until the red indicator goes out to

indicate that the lower stamp has reached its operating

temperature.

4. Fig. 19: Connect the machine to the compressed air

supply system by installing the compressed air hose

connector to the outlet of the compressed air supply sy-

stem in the operating room. A pressure reducer 1 re-

duces the compressed air to the operating pressure of

6 bar. Check the manometer 2 to see if the correct

operating pressure has been set. The pressure redu-

cer is located at the machine frame below the B ma-

chine.

5. Insert needle, pass top thread through needle and in-

stall bottom thread spool to sewing head (see opera-

ting instructions of sewing head manufacturer or sup-

plier).

NOTE - Passing thread through needle!

On both machines, the program control supports the passing

of the thread through the needle.

Fig. 19