I 2 of 5 minimum label length, I 2 of 5 minimum label length -229, And i 2 of 5 minimum label length – Datalogic Scanning 9500 User Manual

Page 345

Advertising
background image

Interleaved 2 of 5 (I 2 of 5) Enable

Product Reference Guide

6-229

I 2 of 5 Minimum Label Length

This feature specifies the minimum allowable length of an I 2 of 5 label.

To set this feature:

1. Scan the SWITCH bar code.

2. Scan the bar code,

SET I 2 OF 5 MINIMUM LABEL LENGTH

below. You’ll need to cover any unused bar codes on this and the fac-
ing page to ensure that the scanner reads only the bar code you
intend to scan.

3. Scan the appropriate digits from the keypad in Appendix C that rep-

resent the desired minimum label length. The selectable range for
this option is 02 to 50, even numbers only. Pad all single digit num-
bers with a leading zero to yield a two-digit entry (02-50).

4. Complete the programming sequence by scanning the SWITCH

bar code.

SET I 2 OF 5 MINIMUM LABEL LENGTH

NOTE

Length in this case includes check and data characters, but does not include
start or stop characters. This feature applies when

I 2 of 5 Length Control is

set to variable-length decoding.

Minimum label length should be less than or equal to maximum label length.

Advertising
This manual is related to the following products: