The housing and power modules are equipped with temperature-controlled, speed-
regulated fans. This has a number of benefits:
-

Heat sinks can be smaller - compact housing

-

Cooler components - improved efficiency and longer service life

-

Speed regulation of the fan and the design with ball bearings means that energy
consumption and noise pollution are kept to an absolute minimum

-

In the event that the heat cannot be dissipated even when fans are working at
maximum speed (e.g. in switch cabinets that do not have an appropriate heat
dissipation system), a process known as power derating is initiated in order to
protect the FRONIUS IG.
-

A power derating system briefly restricts the output from the FRONIUS IG in
order to prevent the temperature from exceeding the permissible value.

-

Your FRONIUS IG will continue to operate without any down times for as long
as possible.

-

Even if the FRONIUS IG very frequently operates under maximum load, the
fans can be expected to have a service life of around 20 years.

Forced-air venti-
lation

3

outdoor

*

2

3

1

**

IP 43 version:
Fitting the hood
and exhaust pipe

(continued)

Figures 2 and 3 show an exhaust air guide with a bent pipe. We recommend this version
where the air exits in the following situations:
-

On the west side of the building

-

In locations that are exposed to adverse weather conditions

-

In other areas that are subject to water spray

Important! The maximum pipe length must not exceed 5 m. The diameter of the torch
neck supplied (folded spiral seam version) is 224 mm.

*)

In all other air outlet situations, an
exhaust air guide with a straight,
bevelled pipe is sufficient.

**)

A non-return valve must be used in
order to prevent the ingress of cool
outside air. The fall of the pipe to-
wards the outside of the building must
be at least 2°.