Fronius IG 300 User Manual

Page 66

Advertising
background image

58

Following careful testing
and when the mains fre-
quency passes into the per-
missible range, the FRONI-
US IG will resume feeding
power into the mains.

134

Mains frequency in
phase 3 outside the
permissible range

Check mains frequency

If this service code keeps
recurring, contact your
system engineer

Following careful testing
and when the mains condi-
tions are within the permis-
sible range again, the FRO-
NIUS IG will resume feeding
power into the mains.

107

No AC network

Check mains connec-
tions and fuses

If this service code keeps
recurring, contact your
system engineer

Following careful testing
and when the mains condi-
tions are within the permis-
sible range again, the FRO-
NIUS IG will resume feeding
power into the mains.

108

Islanding detected

If this service code keeps
recurring, contact your
system engineer

No power is fed into the
mains

109

General mains fault

If this service code keeps
recurring, contact your
system engineer

Class 1

(continued)

Class 2 service codes can only occur in connection with the optional overvoltage/under-
voltage relay.

Class 2 service codes are also related to the mains parameters. Therefore, some of the
testing methods overlap with those for service class 1. The FRONIUS IG will react in
exactly the same way as with class 1 service codes.

Code

Designation

Manifestation

Remedy

No power is fed into the
mains

The overvoltage/undervol-
tage relay has tripped

210

Mains contactor open

If this service code keeps
recurring, contact your
system engineer

Class 2

Code

Designation

Manifestation

Remedy

Advertising