Fronius IG 300 User Manual

Page 65

Advertising
background image

57

Following careful testing
and when the mains fre-
quency passes into the per-
missible range, the FRONI-
US IG will resume feeding
power into the mains.

104

Mains frequency in all
phases outside the per-
missible range

Check mains frequency

If this service code keeps
recurring, contact your
system engineer

Following careful testing
and when the mains fre-
quency passes into the per-
missible range, the FRONI-
US IG will resume feeding
power into the mains.

114

Mains frequency in
phase 1 outside the
permissible range

Check mains frequency

If this service code keeps
recurring, contact your
system engineer

Following careful testing
and when the mains fre-
quency passes into the per-
missible range, the FRONI-
US IG will resume feeding
power into the mains.

124

Mains frequency in
phase 2 outside the
permissible range

Check mains frequency

If this service code keeps
recurring, contact your
system engineer

Service codes in service class 1 generally only arise momentarily, and are caused by the
public mains network.

The initial response of the FRONIUS IG in this case is to disconnect itself from the
mains. The mains is subsequently checked for the stipulated monitoring period. If no
further problem has been detected by the end of this period, then the FRONIUS IG will
resume feeding power into the mains.

A list of service codes, associated designations, descriptions and corrective actions can
be found in the table below.

Class 1

Following careful testing
and when the mains voltage
passes into the permissible
range, the FRONIUS IG will
resume feeding power into
the mains.

101

Mains voltage in all
phases outside the per-
missible range

Code

Designation

Manifestation

Check mains voltage

If this service code keeps
recurring, contact your
system engineer

Remedy

Following careful testing
and when the mains voltage
passes into the permissible
range, the FRONIUS IG will
resume feeding power into
the mains.

111

Mains voltage in phase
1 outside the permis-
sible range

Check mains voltage

If this service code keeps
recurring, contact your
system engineer

Following careful testing
and when the mains voltage
passes into the permissible
range, the FRONIUS IG will
resume feeding power into
the mains.

121

Mains voltage in phase
2 outside the permis-
sible range

Check mains voltage

If this service code keeps
recurring, contact your
system engineer

Following careful testing
and when the mains voltage
passes into the permissible
range, the FRONIUS IG will
resume feeding power into
the mains.

131

Mains voltage in phase
3 outside the permis-
sible range

Check mains voltage

If this service code keeps
recurring, contact your
system engineer

Advertising
This manual is related to the following products: