Fronius IG 300 User Manual

Page 68

Advertising
background image

60

The power module will au-
tomatically attempt to con-
nect again and, if possible,
will resume feeding power
into the mains

401

Communication with
power module not pos-
sible

Some of the Class 4 service codes necessitate intervention by a FRONIUS-trained
service technician.

Code

Designation

Manifestation

Class 4

If a service code appears
frequently:

Notify FRONIUS-trained
service engineer

Remedy

The power module will au-
tomatically attempt to con-
nect again and, if possible,
will resume feeding power
into the mains

402

Communication with
EEPROM not possible

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

The power module will au-
tomatically attempt to con-
nect again and, if possible,
will resume feeding power
into the mains

403

EEPROM defective

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Power module discon-
nected from mains for safe-
ty reasons

406

AC temperature sensor
defective

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

2-pin plug inserted in wrong
socket

410

Service plug has not
been connected in its
original position

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Power module discon-
nected from mains for safe-
ty reasons

407

DC temperature sensor
defective

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Power module discon-
nected from mains for safe-
ty reasons

408

Feeding DC into the
mains

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Power module not con-
nected to the mains

409

No +15 V supply for the
electronic control sys-
tem

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer