61

LED is steady orange, po-
wer module then attempts a
restart

425

Communication with
the power module is not
possible

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Earth current at the solar
modules

434

Earthing fault detected

Check cabling on the DC
side and fuse on the
FRONIUS IG

Fixing voltage is lower than
actual MPP voltage

412

Fixing voltage mode
has been selected in-
stead of MPP voltage
mode, and the fixing
voltage has been set
at too low a value.

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Because the mains conditi-
ons have changed signifi-
cantly, the power module is
disconnected briefly from
the mains.

413

Control problems

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Memory component erased

414

EEPROM defective

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

LED is steady orange, po-
wer module then attempts a
restart

416

Communication with
IG-Ctrl not possible

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Power module locked out,
critical error indicated by red
LED

417

Two power modules
have the same PCB
number

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Power module locked out,
critical error indicated by red
LED

419

Two or more power
modules with identical
software serial number
detected

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Power module locked out,
critical error indicated by red
LED

421

PCB number has been
set incorrectly

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Class 4

(continued)

FRONIUS IG is not con-
nected to the mains

439

Transformer not con-
nected

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

FRONIUS IG is not con-
nected to the mains

440

Jumper short circuit

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Code