Fronius IG 300 User Manual

Page 70

Advertising
background image

62

Power module is restarted
after a cooling-down period

441

Failure of a power-mo-
dule fan

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

Code

Designation

Manifestation

Remedy

Class 4

(continued)

Power cannot be fed into
the mains symmetrically
because of a mains fault

The FRONIUS IG is locked
out

The red LED indicates a cri-
tical error

442

No phase master found

Disconnect DC side

If a service code appears
frequently: Notify FRO-
NIUS-trained service
engineer

FRONIUS IG address has
been assigned twice

The LocalNet components
required are in the FRONI-
US IG: However, no com-
munication is possible

504

Communication with
LocalNet not possible

Change FRONIUS IG
address (see chapter
entitled „The Setup
Menu“)

The status message
goes off once the FRO-
NIUS IG address has
been changed

Some items of data from the
service menu are lost

505

EEPROM defective

Fault rectified automati-
cally

Some items of data from the
„Total“ menu are lost

506

EEPROM defective

Fault rectified automati-
cally

Some items of data from the
„Day“/“Year“ menu are lost

507

EEPROM defective

Fault rectified automati-
cally

The address for data com-
munication is no longer
stored

508

FRONIUS IG address
contains an error

Redefine address

Excessive temperature in
device despite the fact that
little power is being deliver-
ed

501

Faulty fan

Ventilation slots blo-
cked

Class 5 service codes do not generally interfere with feeding power into the mains. A
service code is displayed until it is acknowledged by pressing a key (however, the
FRONIUS IG continues to operate normally in the background).
-

Press any key

-

The error message disappears from the display

Code

Designation

Description

Contact your system en-
gineer

Uncover ventilation slots

Remedy

While automatically measu-
ring the insulation, the FRO-
NIUS IG has detected an
insulation fault to earth

502

Insulation value too low

Check the insulation of
your photovoltaic system

Service code appears
again: Contact your sys-
tem engineer

Class 5