Configuration Parameters

AS56 and AS56

Plus

User Manual

3-5

7.

Network Diagnostics. This entry determines the Access Sy stem56’s
ability to respond to diagnostic commands received from the network
supplier. Repeatedly

SELECT

to choose between Yes and No.

User equipment must always respond to network-generated
diagnostic commands. Select Yes unless the commands are to be
passed to another T1 device that will respond.

8.

NI Density. This information must be obtained from the network
supplier. Depress

SELECT

to choose Clear or 62411. A Clear

network imposes no “ones density” requirements on the user. A
62411 network complies with AT&T Technical Reference #62411
and limits Access Sy stem56 transmission to no more than fifteen
consecutive zeroes.

If the Line Code entry is B8ZS, choose Clear. If the Line Code entry
is AMI, choose 62411.

9.

NI CFA. Depress

SELECT

to choose between Yes and No.

Yes causes the unit to discard data and send a “yellow alarm” if it is
in a “red alarm” condition for three seconds.

NI Configuration

NTWK Diag.: XXX

DOWN

to

display:

NI Configuration

Density: XXXX

DOWN

to

display:

NI Configuration

NI CFA:_XXX