Configuring and Installing the Access Syste m56

3-22

AS56 and AS56

Plus

User Manual

56/64 kbps mode
self testing

If the Local Loop is presently Off, the Network

ALARM

indicator should

be illuminated. If the Local Loop is presently On, the Network

ALARM

indicator should be extinguished. Depress

SELECT

to turn the loop On

and Off while confirming proper functioning of the Network

ALARM

indicator. Leave the Local loop in the On condition.

Main Menu HH:MM

_Diagnostics

From

Main Menu,

UP/DOWN

to

display:

Diagnostics

_Ntwk Port

SELECT

to display:

Ntwk Diagnostics

Local Loop..:_Off

SELECT

to

display:

Ntwk Diagnostics

DSU Loop..:_Off

DOWN

as required

to display:

Ntwk Diagnostics

DSU Loop..:_On

If necessary,

SELECT

to display:

Ntwk Diagnostics

BERT.....:_Off

DOWN

as required

to display: