Testing the Access System 56

4-8

AS56 and AS56

Plus

User Manual

Serial Port BERT

The Serial Port (DTE) BERT can be used as a part of many different test
configurations. It is most valuable with both the Local and Remote Serial
Port Loops activated. The local end of the recommended configuration is
shown below.

The “Local” Errored Seconds are counted by the detector toward the left
side in the figure. The “Remote” Errored Seconds are counted by the
detector toward the right side.

WHEN TESTING IS COMPLETED, BE SURE TO TURN THE LOOP AND
BERT “OFF”.

Use

SELECT

and

UP/DOWN

as required to:

Turn ON the Local and/or Remote Loop.

Confirm/set the BER pattern generator to 2047.

Zero out the local and remote Errored Seconds counters.

Zero out the seconds/test counter.

Inject errors to confirm test configuration.

Diagnostics

_Serial Port

From Diag. Menu,

UP/DOWN

to

display:

SP Diagnostics

Local Loop.: Off

SELECT

to display:

Generator

Test Pattern

Detector

Generator

Detector

To

DTE

1.536 Mbps

1.544 Mbps

Serial Port

BERT and

Payload

Networ

Interface

Loop ON