Access system56 self-testing, T1/ft1 mode self- testing, Access syst em56 self-testing -20 – Verilink AS56/56Plus (896-502588-001) Product Manual User Manual
Page 44: T1/ft1 mode self-testing -20, Access sy stem56 self-testing

Configuring and Installing the Access Syste m56
3-20
AS56 and AS56
Plus
User Manual
Access Sy stem56 Self-Testing
The self-testing can be performed via either the Acces s System56 control
panel or an external terminal or PC. The instructions below assume that
the unit’s control panel is being used. Chapte r6, Auxiliary Ports,
describes usage of an external terminal.
T1/FT1 mode self-
testing
If the Local Loop is presently Off, the Network
ALARM
indicator should
be illuminated. If the Local Loop is presently On, the Network
ALARM
indicator should be extinguished. Depress
SELECT
to turn the loop On
and Off while confirming proper functioning of the Network
ALARM
indicator. Leave the Local loop in the On condition.
Main Menu HH:MM
_Diagnostics
From Main Menu,
UP/DOWN
to
display:
Diagnostics
_Ntwk Port
SELECT
to display:
NI Diagnostics
Local Loop..:_Off
SELECT
to
display: