Events

AS56 and AS56

Plus

User Manual

5-11

T1/FT1 Events

Type

Text

Description

System

UNIT START

Access Syst em56 power up or initialization sequence

BRAM CLEAR

Non-volatile memory has been cleared

CFG ERROR

Error detected in non-volatile memory

Alarm

NI RED

Network Interface is in Red Alarm

NI AIS

Network Interface is receiving all “Ones”

NI YEL

Network Interface is receiving Yellow Alarm

NI CRC

Network Interface is experiencing CRC6 Errors

NI LOS

Network Interface is in a Los of Signal condition

NI FSS

Network Interface is in a Failed Signal State

NI FERR

Network Interface is experiencing Framing Errors

Diagnostic

DTE LL

Serial Port is in Local Digital Loopback

DTE RL

Serial Port is in Remote Digital Loopback

NI LLB

The Network Interface is in Local Line Loopback

NI RLB

The Network Interface is in Remote Line Loopback

NI PLLB

The Network Interface is in Payload Loopback

NI CSU LL

The Network Interface is in Local CSU Loopback