Payload bert, Payload bert -3 – Verilink AS56/56Plus (896-502588-001) Product Manual User Manual

Page 57

Advertising
background image

Testing in T1/FT1 Mode

AS56 and AS56

Plus

User Manual

4-3

Payload BERT

The Payload BERT is useful in a point-to-point environment. The Access
System 56 units at both ends of the circuit must be placed in a Payload
BERT condition with the same BER pattern.

SELECT

as required to choose the desired Bit Error Rate pattern of 2047,

1 of 8, 3 of 24, or All Ones.

If the BER pattern was changed in the previous step, the BERT must be
turned OFF and back ON again to establish the new pattern.

SELECT

as

required to turn the BERT Off/On.

If the CSU portions of the Access Syste m56 units and the data link are all
functioning properly, the Seconds/Test at both units will increment while
the Errored Seconds at both units will not increment.

WHEN TESTING IS COMPLETED, BE SURE TO TURN BOTH BERT
TESTS “OFF”.

Diagnostics

_Ntwk Port

From Diag. Menu,

UP/DOWN

to

display:

NI Diagnostics

Tst Pat._XXX

SELEC

, then

DOWN

to

display:

NI Diagnostics

BERT......:_On

DOWN

and

SELECT

as required to

display:

NI Diagnostics

Sec/Test.:_00000

DOWN

and

SELECT

as required to

display: