Payload bert, Payload bert -3 – Verilink AS56/56Plus (896-502588-001) Product Manual User Manual
Page 57

Testing in T1/FT1 Mode
AS56 and AS56
Plus
User Manual
4-3
Payload BERT
The Payload BERT is useful in a point-to-point environment. The Access
System 56 units at both ends of the circuit must be placed in a Payload
BERT condition with the same BER pattern.
SELECT
as required to choose the desired Bit Error Rate pattern of 2047,
1 of 8, 3 of 24, or All Ones.
If the BER pattern was changed in the previous step, the BERT must be
turned OFF and back ON again to establish the new pattern.
SELECT
as
required to turn the BERT Off/On.
If the CSU portions of the Access Syste m56 units and the data link are all
functioning properly, the Seconds/Test at both units will increment while
the Errored Seconds at both units will not increment.
WHEN TESTING IS COMPLETED, BE SURE TO TURN BOTH BERT
TESTS “OFF”.
Diagnostics
_Ntwk Port
From Diag. Menu,
UP/DOWN
to
display:
NI Diagnostics
Tst Pat._XXX
SELEC
, then
DOWN
to
display:
NI Diagnostics
BERT......:_On
DOWN
and
SELECT
as required to
display:
NI Diagnostics
Sec/Test.:_00000
DOWN
and
SELECT
as required to
display: