Access Syst em56 Self-Testing
AS56 and AS56
Plus
User Manual
3-23
Confirm that the Seconds/Test is properly incrementing and then depress
UP
to confirm that the Errored Seconds is not incrementing. If the unit is
receiving errored seconds, confirm your configuration and run the self-
testing again. If the unit still indicates “errored seconds”, contact our
Technical Assistance Center.
Turn Off the BERT and the Local Loop.
Cycle through the Diagnostics menus and confirm that all test functions
(loops and BERT) are Off. (If necessary, turn them Off).
If the unit is being used in a point-to-point configuration, configure and
self-test the remote unit. If the unit is being used in an Integrated Access
T1 environment, configure and self-test all remaining units.
Ntwk Diagnostics
BERT......:_2047 or
If necessary,
SELECT
to display:
Ntwk Diagnostics
Loc ES...:_00000
DOWN
and
SELECT
to display:
Ntwk Diagnostics
Sec/Test.:_00000
DOWN
as required and
SELECT
to display:
All 0s