Access Syst em56 Self-Testing

AS56 and AS56

Plus

User Manual

3-21

Confirm that the Seconds/Test is properly incrementing and then depress

UP

to confirm that the Errored Seconds is not incrementing. If the unit is

receiving errored seconds, confirm your configuration and run the self-
testing again. If the unit still indicates “errored seconds”, contact our
Technical Assistance Center.

Turn Off the BERT and the Local Loop.

Cycle through the Diagnostics menus and confirm that all test functions
(loops and BERT) are Off. (If necessary, turn them Off).

If the unit is being used in a point-to-point configuration, configure and
self-test the remote unit. If the unit is being used in an Integrated Access,
Fractional T1 environment, configure and self-test all remaining units.

NI Diagnostics

BERT......:_Off

DOWN

to display:

NI Diagnostics

BERT......:_On

If necessary,

SELECT

to display:

NI Diagnostics

Err Secs.:_00000

DOWN

and

SELECT

to display:

NI Diagnostics

Sec/Test.:_00000

DOWN

as required and

SELECT

to display: