Verilink AS56/56Plus (896-502588-001) Product Manual User Manual

Page 50

Advertising
background image

Configuring and Installing the Access Syste m56

3-26

AS56 and AS56

Plus

User Manual

If the remote end responds properly to this command, the Network

LOOP

indicator will illuminate within approximately ten seconds. If the remote
end does not respond properly, the

LOOP

indicator will remain

extinguished and the LCD panel will change to NI RLB..:_Off.

Confirm that the remote end has responded properly. If it has not, check
the Network cable connections and try again. If it still does not respond,
contact your network supplier. Continue with the following steps only if
the remote end has responded properly.

Confirm that the Seconds/Test is properly incrementing and then depress

UP

to confirm that the Errored Seconds is not incrementing. If the unit is

receiving errored seconds, confirm your configuration and run the testing
again. If the unit still indicates errored seconds, contact our Technical
Assistance Center.

NI Diagnostics

NI RLB..:_Off

DOWN

as required

to display:

NI Diagnostics

NI RLB..:_On

SELECT

to display:

NI Diagnostics

BERT......:_On

DOWN

as required and

SELECT

to display:

NI Diagnostics

Err Secs.:_00000

DOWN

as required and

SELECT

to display:

NI Diagnostics

Sec/Test.:_00000

DOWN

as required and

SELECT

to display: