Configure network port, Configure network port -4, Step 10 – Verilink DIDCSU 2912 (880-502646-001) Product Manual User Manual

Page 22

Advertising
background image

DIDCSU 2912 Quick Set-Up

2-4

Verilink DIDCSU 2912 User Manual

8. Once the bus assignment has been made, reboot the DIDCSU

by reseating the front module in its slot.

9. Reconnect the Craft cable to the NCM L

OCAL

port. When the

DIDCSU 2912 has completed the reset a process of negotiation
for shelf master will occur. During this time the SYS LED on the
DIDCSU will be amber. Once the SYS LED becomes steady
green, the NCM has control of the DIDCSU—proceed to step 10.

Configure

Network Port

10. From the NCM Craft interface Main Menu (

Figure 2-2

), select

the DIDCSU application module using option “S”, Shelf/Slot.
Note that now the Main Menu shows brackets around the
letter A, indicating the DIDCSU is the currently selected
module.

11. From the Main Menu, select option “C” to start the

configuration task.

Figure 2-4 Configuration Menu

12. From the Configuration Menu (

Figure 2-4

), select option “P” to

access the T1 Port Configuration Menu (

Figure 2-5

).

-- DIDCSU 2912 CONFIGURATION MENU --

-- DIDCSU 2912 CONFIGURATION MENU --

-- DIDCSU 2912 CONFIGURATION MENU --

-- DIDCSU 2912 CONFIGURATION MENU --

P) T1 port D) data port

P) T1 port D) data port

P) T1 port D) data port

P) T1 port D) data port
X) exit this screen

X) exit this screen

X) exit this screen

X) exit this screen

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >