Figure 2-5 – Verilink DIDCSU 2912 (880-502646-001) Product Manual User Manual

Page 23

Advertising
background image

DIDCSU 2912 Quick Set-Up

Verilink DIDCSU 2912 User Manual

2

-

5

Figure 2-5 T1 Port Configuration Menu

Place Ports In

Service

13. In the T1 Port Configuration Menu, type the letter “

I

” and the

number “1”, press E

NTER

, then type “Y”,and press E

NTER

, to

place Net Port 1 In Service. Type “

I

2”, press E

NTER

, then

respond by pressing “Y”, E

NTER

, to place Net Port 2 In Service.

NOTE: For the remainder of this section you will not be instructed

each time you should press the E

NTER

key. In general, E

NTER

is

used after each command or text entry.

Select ESF Framing

14. Type “F1”, and “2” for ESF framing for Net Port 1. Type “F2”

and “2” for ESF framing for Net Port 2.

Select B8ZS Line

Coding

15. Type “L1”, then “2” to select B8ZS as the line coding for Net

Port 1. Type “L2”, then “2” to select B8ZS as the line coding for
Net Port 2.

Set Line Build Out

to 0db

16. Type “B1”, then “1” to select 0db as the line build out for Net

Port 1. Type “B2”, then “1” to select 0db as the line build out
for Net Port 2.

Set Density

Enforcement to

None

17. Type “ND1”, then “1” to select NONE as the network density

for Net Port 1. Type “ND2”, then “1” to select NONE as the
network density for Net Port 2.

-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --

-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --

-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --

-- DIDCSU 2912 T1 PORT CONFIGURATION MENU --

PORT 1 PORT 2

PORT 1 PORT 2

PORT 1 PORT 2

PORT 1 PORT 2

In) In Service YES YES

In) In Service YES YES

In) In Service YES YES

In) In Service YES YES
Fn) Frame Format SF ESF

Fn) Frame Format SF ESF

Fn) Frame Format SF ESF

Fn) Frame Format SF ESF
Ln) Line Coding AMI AMI

Ln) Line Coding AMI AMI

Ln) Line Coding AMI AMI

Ln) Line Coding AMI AMI
Bn) Line Build Out 0db 0db

Bn) Line Build Out 0db 0db

Bn) Line Build Out 0db 0db

Bn) Line Build Out 0db 0db
NDn) Network Density NONE NONE

NDn) Network Density NONE NONE

NDn) Network Density NONE NONE

NDn) Network Density NONE NONE
NLn) Network Initiated Loop NO NO

NLn) Network Initiated Loop NO NO

NLn) Network Initiated Loop NO NO

NLn) Network Initiated Loop NO NO
An) Alarm Declare Time(sec) 0 0

An) Alarm Declare Time(sec) 0 0

An) Alarm Declare Time(sec) 0 0

An) Alarm Declare Time(sec) 0 0
DLn) FDL Enable NO NO

DLn) FDL Enable NO NO

DLn) FDL Enable NO NO

DLn) FDL Enable NO NO
PRM Enable NO NO

PRM Enable NO NO

PRM Enable NO NO

PRM Enable NO NO
En) Enable Inband/ISDN both dis both dis

En) Enable Inband/ISDN both dis both dis

En) Enable Inband/ISDN both dis both dis

En) Enable Inband/ISDN both dis both dis
Sn) Inband Timeslot 1 1

Sn) Inband Timeslot 1 1

Sn) Inband Timeslot 1 1

Sn) Inband Timeslot 1 1
F) FDL configuration

F) FDL configuration

F) FDL configuration

F) FDL configuration

T) Timing

T) Timing

T) Timing

T) Timing
X) Exit this screen

X) Exit this screen

X) Exit this screen

X) Exit this screen

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >

Advertising