DIDCSU 2912 Quick Set-Up

Verilink DIDCSU 2912 User Manual

2

-

21

16. Type “DP”, then at the prompt use “1,2”

for the shelf/slot

address. At the next prompt type “4” for Data Port 2.

17. Type “SM”, and respond “N” if you are asked whether this is an

unframed E1 circuit. Type “1

----15” to specify the timeslots.

18. Type “DM”, and respond “N” if you are asked whether this is

an unframed E1 circuit. Type “1

----15” to specify the timeslots.

19. Type “U” to assign the bus. As with the first circuit, no bus is

required because the source and destination ports are on the
same DIDCSU module. The menu returns with the bus set to
INT.

20. Type “S” to setup the circuit. A prompt is displayed indicating

a successful circuit build.

21. Connect the two E1 circuits. Observe that the front panel NET

LEDs turn green within 15 seconds.

22. Connect the Data Terminal Equipment (DTE).