DIDCSU T1 Version

Verilink DIDCSU 2912 User Manual

3-29

Display Alarm

Buffers

To display the alarm buffer, enter the letter “O” in the Net Port
Alarm Menu. The Display Alarm Buffer displays all major and
minor alarms that have occurred at each port. When an alarm is
cleared, the time stamp changes to reflect the time the alarm was
cleared.

Rn

Remote Alarm Indication (RAI) Threshold/RAI Interval: Use this option to

indicate a monitoring interval that is greater than the threshold.

In the Superframe format, an RAI consists of Bit 2 of all 24 channels set

to zero.

In ESF format, an RAI is a repeating pattern of eight ones followed by

eight zeros transmitted over the ESF Data Link.

Threshold:

1—86400

0 to disable

Interval:

1—86400

seconds

An

Alarm Indication Signal (AIS) Threshold/AIS Interval: Use this option to

indicate a monitoring interval that is greater than the threshold.

Threshold:

1—86400

0 to disable

Interval:

1—86400

seconds

Bn

Bipolar Violation (BPV) Threshold/BPV Interval: Use this option to

indicate a monitoring interval that is greater than the threshold.

Threshold:

1—86400

0 to disable

Interval:

1—86400

seconds

En

Errored Seconds (ES) 15 min. Threshold/ES 24 hr. Threshold: An ES

alarm indicates a second with one or more ESF error events.

Enter the maximum number of ES to be allowed in 15 minutes and 24

hours.

15 minute

Threshold:

1— 900

0 to disable

24 hour

Threshold:

1—86400

0 to disable

Sn

Severely Errored Second (SES) 15 min. Threshold/SES 24 hr. Threshold:

Select a threshold level.

Enter the maximum number of SES to be allowed in 15 minutes and 24

hours.

15 minute

Threshold:

1—900

0 to disable

24 hour

Threshold:

1—86400

0 to disable

In

Bit Error Rate (BER) Threshold: Select a threshold level. Selecting

10

-9

(1 per billion bits) will report more errors than 10

-4

(1 per thousand

bits).

1) DISABLE

2) 10E-4

3) 10E-5

4) 10E-6

5) 10E-7

6) 10E-8

7) 10E-9

X

Exit the Net Port Alarm Threshold Configuration Menu

Command

Description

Options