Figure 3-16 – Verilink DIDCSU 2912 (880-502646-001) Product Manual User Manual

Page 64

Advertising
background image

DIDCSU T1 Version

3-24

Verilink DIDCSU 2912 User Manual

Figure 3-16 24 hr T1 Performance Data Summary

Following is a brief description of the 24 hr T1 Performance Data
Summary fields. When one of these options is selected, the
previous 24-hour data displays in 15-minute increments for a total
of 96 blocks of time.

Table 3-12 24 hr T1 Performance Data Summary

-- DIDCSU 2912 PERFORMANCE/STATUS MENU --

-- DIDCSU 2912 PERFORMANCE/STATUS MENU --

-- DIDCSU 2912 PERFORMANCE/STATUS MENU --

-- DIDCSU 2912 PERFORMANCE/STATUS MENU --

24hr T1 Performance Data Summary

24hr T1 Performance Data Summary

24hr T1 Performance Data Summary

24hr T1 Performance Data Summary

ES BES SES UAS LOF LOSS AISS

ES BES SES UAS LOF LOSS AISS

ES BES SES UAS LOF LOSS AISS

ES BES SES UAS LOF LOSS AISS
PORT 1 0 0 0 0 0 0 0

PORT 1 0 0 0 0 0 0 0

PORT 1 0 0 0 0 0 0 0

PORT 1 0 0 0 0 0 0 0
PORT 2 0 0 0 0 0 0 0

PORT 2 0 0 0 0 0 0 0

PORT 2 0 0 0 0 0 0 0

PORT 2 0 0 0 0 0 0 0

En) Errored Seconds Un) Unavailable Seconds

En) Errored Seconds Un) Unavailable Seconds

En) Errored Seconds Un) Unavailable Seconds

En) Errored Seconds Un) Unavailable Seconds
Bn) Bursty Seconds Sn) Severely Errored Seconds

Bn) Bursty Seconds Sn) Severely Errored Seconds

Bn) Bursty Seconds Sn) Severely Errored Seconds

Bn) Bursty Seconds Sn) Severely Errored Seconds
Ln) LOS Seconds Fn) SEF Seconds

Ln) LOS Seconds Fn) SEF Seconds

Ln) LOS Seconds Fn) SEF Seconds

Ln) LOS Seconds Fn) SEF Seconds
Dn) LOF Seconds On) OOF Seconds

Dn) LOF Seconds On) OOF Seconds

Dn) LOF Seconds On) OOF Seconds

Dn) LOF Seconds On) OOF Seconds
An) AIS Seconds

An) AIS Seconds

An) AIS Seconds

An) AIS Seconds
Mn) Loss of Frame Counts Zn) AIS/SEF Seconds

Mn) Loss of Frame Counts Zn) AIS/SEF Seconds

Mn) Loss of Frame Counts Zn) AIS/SEF Seconds

Mn) Loss of Frame Counts Zn) AIS/SEF Seconds
Qn) Errored Seconds Type A Hn) Frame Errors

Qn) Errored Seconds Type A Hn) Frame Errors

Qn) Errored Seconds Type A Hn) Frame Errors

Qn) Errored Seconds Type A Hn) Frame Errors
Jn) Degraded Minutes In) Error Free Seconds

Jn) Degraded Minutes In) Error Free Seconds

Jn) Degraded Minutes In) Error Free Seconds

Jn) Degraded Minutes In) Error Free Seconds
Rn) Reset Registers X) exit this screen

Rn) Reset Registers X) exit this screen

Rn) Reset Registers X) exit this screen

Rn) Reset Registers X) exit this screen

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >

A [0.0.0.204] [1,2] DIDCSU 2912 >

Command

Description

En

Errored Seconds (ES): A second with one or more AIS, LOS, or LOF defects.

Un

Unavailable Seconds (UAS): Counted for every second in which an Unavailable Signal State

occurs with the onset of 10 contiguous SES errors. It is also defined as the number of

seconds a service is unavailable due to a Loss-of-Frame (LOF) condition. The UAS condition

is stopped when the failure condition clears.

Bn

Bursty Seconds (BES): A second having between 2 and 319 CRC-6 (Cyclic Redundancy

Check) error events.

Sn

Severely Errored Seconds (SES): This error counts one second intervals with an AIS or CRC

error.

Ln

Loss-of-Signal (LOS) Seconds: A second during which the DIDCSU is in a Loss-of-Signal

state. LOS is declared upon detecting 175 consecutive zeros, it is cleared with the receipt

of the next 1 bit.

Fn

Severely Errored Framing (SEF) Seconds: Those seconds in which two or more framing bit

errors occur within a 3-millisecond period. In ESF mode, this interval may or may not

coincide with an ESF multiframe.

Dn

Loss-of-Frame (LOF) Seconds: An LOF alarm is declared when a 3-second interval of

continuous Out-Of-Frame (OOF) or Loss-of-Signal (LOS) state is detected. If at least 10

seconds elapse without an LOS or LOF error, the LOF alarm is cleared.

On

Out-of-Frame (OOF) Seconds: A condition when any three of four consecutive frame bits

received from the T1 line are incorrect.

Advertising