Dimensioning, Cable lengths – HEIDENHAIN PWM 20 User Manual
Page 217
Advertising

218
HEIDENHAIN ATS Software User's Manual
Recommended input circuit of subsequent electronics
TTL
Dimensioning
Cable lengths
The permissible cable length for transmission of the TTL square-wave signals to the
subsequent electronics depends on the edge separation a. It is 100 m max., or 50 m for the fault
detection signal. The supply voltage at the encoder (see specifications) must be ensured. The
sensor lines can be used to measure the voltage at the encoder and, if required, correct it with
an automatic control system (remote sense voltage supply).
Recommended differential line receivers
DS 26 C 32 AT
AM 26 LS 32 (only if a > 0.1 µs)
MC 3486
SN 75 ALS 193
R
1
4.7 k
R
2
1.8 k
Z
0
120
C
1
220 pF
Advertising