Examples of encoders, Code signals, Incremental signals – HEIDENHAIN PWM 20 User Manual
Page 238: Fault detection signal uas, Programming inputs

November 2014
Interface description
239
Examples of
encoders
ROQ 425 programmable
Code signals
Incremental signals
1 Vpp (“Incremental signals 1 Vpp” on page 212)
Fault detection
signal UaS
Programming
inputs
Interfaces
Serial in the SSI (fir tree) or synchronous-serial right-
aligned (programmable) data formats
Data input
Differential line receiver according to EIA standard
RS 485 for the signals CLOCK, CLOCK, DATA and
DATA
Data output
Differential line driver according to EIA standard
RS485 for DATA and DATA signals
Signal level
Differential voltage output
> 2 V (EIA standard RS-485)
Code
Gray code or binary code (programmable)
Direction of rotation
Increasing code values with clockwise or
counterclockwise rotation, viewed from flange side
(programmable)
1 square-wave pulse UaS (HTL)
Improper function = LOW
Proper function = HIGH
Direction of rotation and reset
Inactive
LOW < 0.25 x Up or input open
Active
HIGH > 0.6 x Up
Switching time
t
min
> 1 ms