Page 95

96
HEIDENHAIN ATS Software User's Manual
Example: LC
1
Status display: Errors and warnings
2
Position displays absolute / incremental
3
Signal position; verification whether datum shift is in compliance with EnDat
(yellow symbol = EnDat non-compliant)
4
Different velocity ranges
5
Permitted accuracy deviations [LSB] at defined velocity ranges [m/min]
6
Velocity at deviation
7
Determined deviation spans [LSB] of the different velocity ranges
8
Reset deviation spans
Invert counting direction of incremental counter
Display details on alarms and warnings
Note
If the signal position is "yellow" (datum is EnDat non-compliant), a TNC control generates an
error message. Depending on the TNC's signal resolution an EnDat non-compliant datum
shift may result in a dimensional error that is beyond the accuracy specifications of the
machine.