19  Parameter Lists

SMA America, LLC

162

SI4548-6048-US-BE-en-20

Operating Manual

133# Generator State

134# Device Meters

No. Name

Description

Value clear
text (No.)

Explanation

01

GnDmdSrc

Source for generator
request

None (1)

No request

Bat (2)

Dependent on battery state of
charge

Lod (3)

Load-dependent

Tim (4)

Time-controlled

Run1h (5)

Requested for 1 hour

Start (6)

Manually started

ExtSrcReq (7) Requested via an external

source

02

GnStt

Generator state

Off (1)

Off

Init (2)

Init

Ready (3)

Waiting for request (ready)

Warm (4)

Warming up

Connect (5)

Connecting

Run (6)

Operation

Retry (7)

Restarting

Disconnect (8) Split
Cool (9)

Cooling down

Lock (10)

Locked after error

Fail (11)

Error

FailLock (12)

Locked after error occurred.

03

GnRmgTm

Remaining time of the
generator (minimum
run time) in hours,
minutes and seconds

04

GnRnStt

Status generator
feedback on the master

Off (1)

off

On (2)

on

No. Name

Description

01

ExtPwrAt

Active power of the external source in kW

02

ExtVtg

Voltage of the external source in V

Advertising