6.2 System I/O Error Status

6.2.1 System I/O Error Status by Controllers

6-3

6

T

roubleshooting

6.2 System I/O Error Status

6.2.1 System I/O Error Status by Controllers

The following shows the system I/O error status of the MP2000 Series Machine Controller.
Refer to 5.3.1 Displaying a Register List on page 5-14 and specify a system register number “SWxxxxx” to access.

( 1 ) MP2100M Machine Controller

∗ Racks 2 to 4 can be used only when using MP2100MEX.

Name

Register No.

Remarks

I/O Error Count

SW00200

Number of I/O error occurrences

Number of Input Errors

SW00201

Number of input error occurrences

Input Error Address

SW00202

Address of the latest input error (IWxxxx register number)

Number of Output Errors

SW00203

Number of output error occurrences

Output Error Address

SW00204

Address of the latest output error
(OWxxxx register number)

Reserved by System

SW00205

(Not used)

SW00206
SW00207

I/O Error Status

SW00208 to SW00215

MP2100M Machine Controller error status

SW00216 to SW00223

Reserved by the system

SW00224 to SW00228

SVB-01 Module error status

SW00229 to SW00239

Reserved by the system

SW00240 to SW00247

Error status of slot 1 of rack 2

*

(Depends on the mounted module and error code.)

SW00248 to SW00255

Error status of slot 2 of rack 2

*

(Depends on the mounted module and error code.)

SW00256 to SW00263

Error status of slot 3 of rack 2

*

(Depends on the mounted module and error code.)

SW00264 to SW00271

Error status of slot 4 of rack 2

*

(Depends on the mounted module and error code.)

...

...

SW00448 to SW00455

Error status of slot 9 of rack 4

*

(Depends on the mounted module and error code.)