Yaskawa CM013 V7 DeviceNet Option User Manual

Page 38

Advertising
background image

Supported Objects 2-17

Class 121 (79h) - V7 Drive Parameter Object

Parameter

Attribute

Description

Get

Set

Size

n041

41 (29h)

Acc Time 3 (0.1s or 0.01s) (see n018)

X

X

Word

n042

42 (2Ah)

Dec Time 3 (0.1s or 0.01s) (see n018)

X

X

Word

n043

43 (2Bh)

Acc Time 4 (0.1s or 0.01s) (see n018)

X

X

Word

n044

44 (2Ch)

Dec Time 4 (0.1s or 0.01s) (see n018)

X

X

Word

n045

45 (2Dh)

Reserved

X

X

Word

n046

46 (2Eh)

Reserved

X

X

Word

n047

47 (2Fh)

Reserved

X

X

Word

n048

48 (30h)

Reserved

X

X

Word

n049

49 (31h)

Reserved

X

X

Word

n050

50 (32h)

Multifunction Input Terminal S1 Select

X

X

Word

n051

51 (33h)

Multifunction Input Terminal S2 Select

X

X

Word

n052

52 (34h)

Multifunction Input Terminal S3 Select

X

X

Word

n053

53 (35h)

Multifunction Input Terminal S4 Select

X

X

Word

n054

54 (36h)

Multifunction Input Terminal S5 Select

X

X

Word

n055

55 (37h)

Multifunction Input Terminal S6 Select

X

X

Word

n056

56 (38h)

Multifunction Input Terminal S7 Select

X

X

Word

n057

57 (39h)

Multifunction Output Terminal MA/MB Select

X

X

Word

n058

58 (3Ah)

Multifunction Output Terminal P1 Select

X

X

Word

n059

59 (3Bh)

Multifunction Output Terminal P2 Select

X

X

Word

n060

60 (3Ch)

Analog Frequency Reference Gain (%) (Terminal FR)

X

X

Word

n061

61 (3Dh)

Analog Frequency Reference Bias (%) (Terminal FR)

X

X

Word

n062

62 (3Eh)

Analog Frequency Reference Filter Time Constant (0.01s) (Terminal FR)

X

X

Word

n063

63 (3Fh)

Reserved

Word

n064

64 (40h)

Frequency Reference Loss Detect

X

X

Word

n065

65 (41h)

Monitor Output Select

X

X

Word

n066

66 (42h)

Multifunction Analog Output Select (Terminal AM)

X

X

Word

n067

67 (43h)

Analog Monitor Gain

X

X

Word

n068

68 (44h)

Analog Frequency Reference Gain (%) (CN2 Voltage Reference)

X

X

Word

n069

69 (45h)

Analog Frequency Reference Bias (%) (CN2 Voltage Reference)

X

X

Word

n070

70 (46h)

Analog Frequency Reference Filter Time Constant (0.01s) (CN2 Voltage Reference)

X

X

Word

n071

71 (47h)

Analog Frequency Reference Gain (%) (CN2 Current Reference)

X

X

Word

n072

72 (48h)

Analog Frequency Reference Bias (%) (CN2 Current Reference)

X

X

Word

n073

73 (49h)

Analog Frequency Reference Filter Time Constant (0.01s) (CN2 Current Reference)

X

X

Word

n074

74 (4Ah)

Pulse Train Reference Gain (%) (Terminal RP)

X

X

Word

n075

75 (4Bh)

Pulse Train Reference Bias (%) (Terminal RP)

X

X

Word

n076

76 (4Ch)

Pulse Train Reference Filter Gain (s) (Terminal RP)

X

X

Word

n077

77 (4Dh)

Multifunction Analog Input Selection

X

X

Word

n078

78 (4Eh)

Multifunction Analog Input Signal Select

X

X

Word

n079

79 (4Fh)

Multifunction Analog Input Bias (%)

X

X

Word

n080

80 (50h)

Carrier Frequency Select

X

X

Word

n081

81 (51h)

Momentary Power Loss Ride Thru Select

X

X

Word

n082

82 (52h)

Number of Auto Restart

X

X

Word

n083

83 (53h)

Prohibit Frequency 1 (0.01Hz < 100Hz) (0.1Hz >= 100Hz)

X

X

Word

n084

84 (54h)

Prohibit Frequency 2 (0.01Hz < 100Hz) (0.1Hz >= 100Hz)

X

X

Word

n085

85 (55h)

Prohibit Frequency 3 (0.01Hz < 100Hz) (0.1Hz >= 100Hz)

X

X

Word

n086

86 (56h)

Prohibit Frequency Deadband (0.01Hz)

X

X

Word

n087

87 (57h)

Reserved

Word

n088

88 (58h)

Reserved

Word

Advertising
This manual is related to the following products: