DeviceNet™ Simplified Start-up Procedure

The following is a quick reference guide to install and configure the drive’s option. For more details, please refer to the drive’s
DeviceNet Technical Manual sections referenced.

1. Verify that the drive functions properly without the option installed. This includes running the drive from the operator

keypad, without communications.

2. Turn off the drive power supply and wait for at least 1 minute for the charge lamp to be completely out before

removing the operator and front cover. Remove the option hold-down tab on the left side of the drive case by
carefully compressing the top and bottom until it becomes free of its holder. Lift it out.

3. Install the option onto the drive. Mount the DeviceNet unit onto the drive making sure to connect 2CN securely. Replace

the option hold-down. Install the operator keypad and front cover back onto the unit after securing the DeviceNet unit
with screw.

4. Connect the DeviceNet communication wires to the screw terminals on the option.

5. Using the DIP switch bank on the DeviceNet option kit, set communication baud rate (switch 1, 2) and MAC ID

(switch 3 – 8). Be sure to verify that no devices on the network have duplicate MAC IDs.

1

2

3

4

5

B K B L

W H R D

G R

BL WH

BK GR RD

Table 2: DeviceNet Terminal Block Connections

Terminal

No.

Terminal

Color

Name

Wiring

Color

Content

1

Black

V-

Black

Communication power supply GND

2

Blue

CAN_L

Blue

Communication data low side

3

Green

Shield

Bare

Shield wire

4

White

CAN_H

White

Communication data high side

5

Red

V+

Red

Communication power supply +24V

dc

ON

OFF

1

2

3

4

5

6

7

8

Baud Rate

1 2
OFF OFF 125kbps
OFF

ON

250kbps

ON

OFF 500kbps

ON ON

Not Allowed

MAC ID

3 4 5 6 7 8

OFF OFF OFF OFF OFF OFF 0

OFF OFF OFF OFF OFF

ON

1

OFF OFF OFF OFF

ON

OFF 2

OFF OFF OFF OFF

ON

ON

3

ON ON ON ON ON

OFF 62

ON ON ON ON ON ON

63

Note: Setting the “Not Allowed”

baud rate configuration

(Switch 1 and 2 “ON”)

causes a “BUS” fault on

the Digital Operator.

Fig. 2 DeviceNet DIP Switch Settings