Yaskawa DeviceNet Option Card CM059 User Manual

Page 43

Advertising
background image

43

Standard Drive Control Output Instance 151 (97 Hex)

This I/O instance is for the input/output functions as well as the expansion I/O instance functions. This instance is for Yaskawa

series drives only, and is not interchangeable with other DeviceNet drives, Assembly Object Class (04 Hex) Attribute (03

Hex). Both input and output use 8 bytes each.

Table 21: Standard Drive Control Instance 151 (97 Hex) (OUTPUT ASSEMBLY)

*1

Byte

Bit 7

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

Fault

Alarm

Inverter

Ready

Speed

Agree

During

reset

During
reverse

During

zero

speed

During Run

1

Terminal

M5-M6

Terminal

M3-M4

Terminal

M1-M2

Local/

Remote

During

UV

During

OPE

2

Speed Actual (Lower Byte)

3

Speed Actual (Upper Byte)

4

5

6

Output Current Monitor (Lower Byte)

7

Output Current Monitor (Upper Byte)

Data

Name

Description

Byte 0, Bit 0

During Run

The drive run status is displayed.
0: During stop
1: During Forward/reverse/DC braking

Byte 0, Bit 1

During Zero Speed

The drive run status is displayed.
0: During forward/reverse
1: During stop/DC braking

Byte 0, Bit 2

During Reverse Run

The drive run status is displayed.
0: During forward run
1: During reverse run/reverse command input

Byte 0, Bit 3

During Reset Input

The drive reset signal input status is displayed.
0: Off
1: During reset signal input

Byte 0, Bit 4

Speed Agree

The drive frequency agree detection status is displayed.
0: During stop/acceleration and deceleration
1: Frequency agree

Byte 0, Bit 5

Inverter Ready

The drive ready status is displayed.
0: During fault detection/ready
1: Ready

Byte 0, Bit 6

Alarm

The drive alarm detection status is displayed.
0: Normal
1: During alarm detection

Byte 0, Bit 7

Fault

The drive fault detection status is displayed.
0: Normal
1: During fault detection

Byte 1, Bit 0

During OPE

The drive Modbus parameter setting error (OPE) detection status is
displayed.
0: Normal
1: During OPE, (OPE1-OPE11) fault detection

*1 Drive products may provide additional inputs and outputs that are not supported through DeviceNet. For example, G7 has 5

digital outputs; however, only 3 digital outputs are supported through DeviceNet.

Advertising