ProSoft Technology MVI56E-MNETR User Manual

Page 41

Advertising
background image

Start Here

MVI56E-MNETR ♦ ControlLogix Platform

User Manual

Modbus TCP/IP Interface Module with Reduced Data Block


ProSoft Technology, Inc.

Page 41 of 153

August 31, 2009

3 Fill in the module properties as follows:

Parameter Value

Name

Enter a module identification string. Example: MNETR_2

Description

Enter a description for the module. Example: Modbus TCP/IP Interface
Module with Reduced Data Block

Comm Format

Select DATA-INT

Slot

Enter the slot number in the rack where the ModelNumber> module is
located.

Input Assembly
Instance

1

Input Size

42

Output Assembly
Instance

2

Output Size

42

Configuration
Assembly Instance

4

Configuration Size

0

4 Click OK to confirm. The new module is now visible:

5 Expand the Tasks folder, and then expand the MainTask folder.
6 On the MainProgram folder, click the right mouse button to open a shortcut

menu. On the shortcut menu, choose N

EW

R

OUTINE

.

7 In the New Routine dialog box, enter the name and description of your

routine, and then click OK.