Default network settings, Default settings – Allen & Heath CQ-20B Ultracompact 20-Channel Digital Mixer (Rackmount/Stagebox) User Manual

Page 131

Advertising
background image

131

User Guide

V1.1.0

Issue 1

Default Network Settings

On first boot or after a reset, network defaults are as follows:

Wi-Fi (CQ-18T, CQ-20B)

SSID is

Visible

.

SSID is [

CQ18T_

XXXX

or

CQ20B_

XXXX

] where

XXXX

are the last 4 digits of

the serial number.

Security is set to ‘

OPEN

(no password is required to connect a device).

Password is set to ‘

DefaultPassword

’.

This will be the password if Security is switched to ‘

WPA2

and changes are applied

without editing the password first.

Country is set to ‘

World-Wide

’.

Channel is set to ‘

AUTO

’.

Ethernet

IP Settings are ‘

Automatic

The unit will be assigned an IP address by a DHCP server (e.g. a connected
router), devices on the same network and in the same network range
running CQ-MixPad can then connect to the unit.

If no address is provided, the CQ will automatically assign itself a local
address. This allows for a direct connection to a computer using a network
cable.

Ethernet (if IP Settings is switched to Manual without other changes)

IP Address

192.168.1.62

Gateway

192.168.1.254

Subnet

24 (255.255.255.0)