HP 2/8q Fibre Channel User Manual

Page 100

Advertising
background image

Switch Manager

100

HP StorageWorks 2/8q Fibre Channel Switch Management User Guide

Out of range domain ID specified.

Verify that all information is valid and retry the

configuration change. Consult the

documentation for valid configurations.
Valid domain IDs must be in the range 1 to

239, and must be unique within a fabric. If the

fabric contains Switch with E_Port switches, all

domain IDs must be in the same range of

sixteen values: 1…16, 17…32, and so on.

Received error in attempting to edit switch

configuration.

or

Received error in attempting to save switch

configuration.

or

Received error in attempting to activate switch

configuration.

Verify that the data is valid, that the user has

permissions to modify the configuration on the

switch, that the switch is reachable in the

fabric, and that the fabric is reachable from

the user’s workstation, and then retry the

configuration change.

Reset will complete shortly. There is a brief loss

of connectivity with switch.

Wait for the switch to become reachable

again. This may take up to one minute.

The new domain ID specified is invalid.
Unable to apply invalid chassis/fabric ID

values

Verify that all information is valid and retry the

configuration change. Consult the

documentation for valid configurations.
Valid domain IDs must be in the range 1 to

239, and must be unique within a fabric. If the

fabric contains Switch with E_Port switches, all

domain IDs must be in the same range of

sixteen values: 1…16, 17…32, and so on.

Unable to apply changes. Failed to obtain

admin privileges.

Verify that another user is not currently

modifying the switch configuration, using

either the management application, or a telnet

login, or any application.

Unable to apply invalid timeout values.

or

Unable to apply invalid IP address.

or

Unable to apply invalid trap address.

or

Unable to apply invalid subnet mask.

or

Unable to apply invalid gateway address.

or

Unable to apply invalid ARP timeout value.

Verify that all information is valid and retry the

configuration change. Consult the

documentation for valid configurations.
Valid domain IDs must be in the range 1 to

239, and must be unique within a fabric. If the

fabric contains Switch with E_Port switches, all

domain IDs must be in the same range of

sixteen values: 1…16, 17…32, and so on.

Table 31: Switch Properties dialog box messages (Continued)

Message

User action

Advertising
This manual is related to the following products: