53 set config threshold parameters – HP 2/8q Fibre Channel User Manual

Page 140

Advertising
background image

Command Line Interface

140

HP StorageWorks 2/8q Fibre Channel Switch Management User Guide

THRESHOLD

Initiates a configuration session by which to generate and log alarms for selected
events. The system displays each event, its triggers, and sampling window one line at a
time and prompts you for a value. For each parameter, enter a new value or press
Enter to accept the current value shown in brackets. These parameters must be saved
in a configuration and activated before they take effect. See the “

Config command

” on

page 119 for information about saving and activating a configuration.

Table 53

describes the Set Config Threshold parameters. The switch shuts down a port if an
alarm condition is not cleared within three consecutive sampling windows (by default
30 seconds). Reset the port to bring it back online. An alarm is cleared when the
threshold monitoring detects that the error rate has fallen below the falling trigger.

Table 53: Set config threshold parameters

Parameter

Description

Threshold Monitoring Enabled

Master enable/disable parameter for all events.

Enables (True) or disables (False) the generation of all

enabled event alarms. The default is False.

CRCErrorsMonitoringEnabled
DecodeErrorsMonitoringEnabled
LoginMonitoringEnabled
LogoutMonitoringEnabled
LOSMonitoringEnabled

The event type enable/disable parameter. Enables

(True) or disables (False) the generation of alarms for

each of the following events:

CRC errors

Decode errors

Device login errors

Device logout errors

Loss-of-signal errors

Rising Trigger

The event count above which a rising trigger alarm is

logged. The switch will not generate another rising

trigger alarm for that event until the count descends

below the falling trigger and again exceeds the rising

trigger.

Falling Trigger

The event count below which a falling trigger alarm is

logged. The switch will not generate another falling

trigger alarm for that event until the count exceeds

the rising trigger and descends again below the

falling trigger.

Sample Window

The period of time in seconds in which to count

events.

Advertising