Shutdown command, Test command, Shutdown – HP 2/8q Fibre Channel User Manual

Page 169: Command, Authority syntax notes, Test, Authority syntax keywords examples

Advertising
background image

Command Line Interface

169

HP StorageWorks 2/8q Fibre Channel Switch Management User Guide

Shutdown

command

Terminates all data transfers on the switch at convenient points and closes the Telnet session.
Always power cycle the switch after entering this command.

Authority

Admin

Syntax

SHUTDOWN

Notes

Always use this command to perform an orderly shut down before removing power from
the switch.

When the shutdown is complete, the Heartbeat LED is extinguished.

Test

command

Tests ports using internal (SerDes level), external (transceiver), and online loopback tests.
Internal and external tests require that the port be placed in diagnostic mode. See the “

Set

command

” on page 135 for information about changing the port administrative state. While

the test is running, the remaining ports on the switch remain fully operational.

Authority

Admin

Syntax

TEST

Keywords

PORT [port_number] [test_type]

Tests the port given by [port_number] using the test given by [test_type]. If you omit
[test_type], Internal is used. [test_type] can have the following values:

internal

—Tests the SerDes. This is the default. The port must be in diagnostics

mode to perform this test.

external

—Tests both the SerDes and transceiver. The port must be in diagnostics

mode to perform this test, and a loopback plug must be installed in the transceiver.

online

—Tests communications between the port and its device node or device loop.

The port being tested must be online and connected to a remote device. The port
passes if the test frame that was sent by the ASIC matches the frame that is received.
This test does not disrupt communication on the port.

CANCEL

—Cancels the online test in progress.

STATUS

—Displays the status of a test in progress, or if there is no test in progress,

the status of the test that was executed last.