Load firmware dialog box messages, Port loopback test dialog box messages – HP 2/8q Fibre Channel User Manual

Page 104

Advertising
background image

Switch Manager

104

HP StorageWorks 2/8q Fibre Channel Switch Management User Guide

Load Firmware dialog box messages

Port Loopback Test dialog box messages

Table 34: Load Firmware dialog box messages

Message

User action

Bad checksum/CRC for the firmware image or

incorrect firmware image for this type of

switch.

Select the correct firmware file for this switch.

File was not found.

Verify that the firmware file specified actually

exists, or specify a new firmware file.

Firmware image had a bad CRC or was

invalid for this type of switch.

Select a valid firmware image for this type of

switch and retry the operation.

Firmware upload status unknown. Image has

been uploaded, but confirmation from the

switch was not received.

The application lost communications with the

switch while the switch was unpacking the

firmware image. If the problem was

temporary, examine the firmware versions on

the switch to verify that the firmware was

unpacked correctly, or upload a new firmware

image to the switch.

The flash memory on the switch may be too

small for this image.

Select an appropriate firmware image for this

type of switch and retry the operation.

Unable to load firmware.

An unspecified error has occurred. Verify that

the user has permissions to modify the

configuration on the switch, that the switch is

reachable in the fabric, and that the fabric is

reachable from the user’s workstation, and

then retry the firmware upload.

Unable to read file.

Verify that the firmware file specified exists

and is readable by the user, on a file system

readable by the user, or specify a new

firmware file.

Table 35: Port Loopback test dialog box messages

Message

User action

Attempt to put port in diagnostic state has

failed. Unable to continue with port test.

Verify that the user has permissions to modify

the configuration on the switch, that the switch

is reachable in the fabric, and that the fabric is

reachable from the user’s workstation, and

then retry the configuration change.

External port test requires a loopback device

be plugged into the selected port. Click “OK”

when loopback device is installed.

Verify that a loopback device is attached to the

port before starting loopback test.

Failed to correctly restore port states for one or

more ports.

Return to the faceplate view and then select

View>Port State to determine which port was

not restored to its original state. Select the

port, and then select Port>Port Properties to

restore the port state.

Invalid frame count value.

or

Invalid frame size. Must be 36 to 2148.

or

Invalid hex pattern. Up to 8 hex digits

allowed.

Verify that all information is valid, and then

retry the loopback test.

Advertising