Register Name:

H1RC, H2RC

Register Description:

HDLC #1 Receive Control, HDLC #2 Receive Control

Register Address:

31h, 32h


Bit #

7

6

5

4

3

2

1

0

Name

RHR

RHMS

-

-

-

-

-

RSFD

Default

0

0

0

0

0

0

0

0


Bit 0/Receive SS7 Fill In Signal Unit Delete (RSFD).

0 = normal operation. All FISUs are stored in the receive FIFO and reported to the host.
1 = When a consecutive FISU having the same BSN the previous FISU is detected, it is deleted without host
intervention.


Bit 1/Unused, must be set to zero for proper operation.


Bit 2/Unused, must be set to zero for proper operation.

Bit 3/Unused, must be set to zero for proper operation.


Bit 4/Unused, must be set to zero for proper operation.


Bit 5/Unused, must be set to zero for proper operation.


Bit 6/Receive HDLC Mapping Select (RHMS)
.

0 = receive HDLC assigned to channels
1 = receive HDLC assigned to FDL (T1 mode), Sa Bits (E1 mode)


Bit 7/Receive HDLC Reset (RHR).
Will reset the receive HDLC controller and flush the receive FIFO. Must be cleared and
set again for a subsequent reset.

0 = normal operation

1 = reset receive HDLC controller and flush the receive FIFO